Powercom BNT 800 V.A 480 watts

Minimum Order: 1

Available Stocks: 10

Weight: 6.60 kg/s

Dimension: 26.00 cm x 9.70 cm x 13.80 cm


₱ 4,104.00

No Reviews yet | Write a Review


Standard Delivery: No

Delivery Period: 3-5 days within Metro Manila and 5-7 days outside Metro Manila

(Note: Delivery period is dependent on Product Delivery)


Cash on Delivery not Available


Powercom BNT 800 V.A 480 watts

 Features :

  • High output and inverter efficiency line-interactive UPS
  • Built-in automatic voltage regulator (AVR)
  • Simulated sine wave output waveforms
  • Green mode setting for energy saving
  • Automatic self-diagnostic and alarm warnings
  • Surge, short circuit, and overload protections
  • Discharge and overcharge protection
  • Scheduling shutdown & reboot function on AP models
  • Events recorder of power incidents on AP models
  • Tel/modem/network surge suppression (Optional)

Specification

MODEL

BNT-400 (A/AP)

BNT-500 (A/AP)

BNT-600 (A/AP)

BNT-800AP

BNT-1000 (AN/APN)

CAPACITY

400VA/240W

500VA/300W

600VA/360W

800VA/480W

1000VA/600W

INPUTVoltage

100V / 110V /115V / 120V ±25%
220V /230V / 240V ±25%

Frequency

50Hz / 60Hz ±10% auto sensing

OUTPUTVoltage

100V / 110V /115V / 120V (±5% on battery )
220V /230V / 240V (±5% on battery )

AVR

When input voltage between -9% to -25% of nominal, increase output by 15%.
When input voltage between +9% to +25% of nominal, decrease output by 13%.

Frequency

50Hz / 60Hz ±1Hz

Waveform

Simulated sinewave

Connections

*Please refer below "Receptacle Options". Customized receptacle can be discussed.

Transfer time

2 to 4 millisecond including detection time (typical)

PROTECTIONOverload

UPS automatic power off if overload exceeds 110% of nominal at 60 seconds; 130% at 3 seconds

Surge

100V / 110V /115V / 120V with 265 Joules, 8/20μS
220V /230V / 240V with 460 Joules, 8/20μS

Short circuit

UPS output cut off immediately or protected by input circuit breaker

Tele-communication

*Optional - none or RJ45

RJ45

Fuse

Yes (fuse or circuit breaker)

Alarm

Buzzer beeps under backup mode, battery low,  battery charging fault, and overload

BATTERYType

Sealed, maintenance-free lead acid battery

Typical recharge time

6 hours to 90%

Battery quantity

12V 7Ah x1

12V 7Ah x1

12V 7Ah x1

12V 9Ah x1

12V 9Ah x1

Backup time for one PC

Approximately 20 minutes

Approximately 20 minutes

Approximately 22 minutes

Approximately 24 minutes

Approximately 27 minutes

Protection

Automatic diagnostics, over-discharge and short circuit protection by fuse

STANDARDSDimension (W x D x H)

97mm x 315mm x 138mm (97mm x 260mm x 138mm for BNT-400A)

Product weight

 5.7kg

6.4kg 

 6.5kg

6.6kg 

 6.7kg

Communication interface

*Optional - none, RS-232 or USB B-type

*Optional - RS-232 or USB B-type

Audible noise

< 40dBA (1m from surface)

Ambient operation

 0 to 40℃, 0 to 95% humidity (non-condensing)

 

Communication Interface

Model

TEL/FAX

RS-232

USB

BNT-400A

BNT-500A

BNT-600A

BNT-400AP 

BNT-500AP

BNT-600AP 

BNT-800AP 

BNT-1000AN

BNT-1000APN

Standard Function  Not Available   ◆Optional

 

Receptacle Options