Powercom VGD - 3000 V.A. - RM 2100 watts

Minimum Order: 1

Available Stocks: 50

Weight: 34.30 kg/s

Dimension: 63.50 cm x 42.80 cm x 8.40 cm


₱ 66,120.00

No Reviews yet | Write a Review


Standard Delivery: No

Delivery Period: 3-5 days within Metro Manila and 5-7 days outside Metro Manila

(Note: Delivery period is dependent on Product Delivery)


Cash on Delivery not Available


Powercom VGD - 3000 V.A. - RM  2100 watts

Features :

  • Double conversion on-line technology with 0.7 power factor in rack mount design
  • Input power factor correction (PFC)
  • Pure sine wave output with less than 3% T.H.D.
  • High efficiency mode selectable
  • Free-run mode setting
  • Active-fan operation dependant on load level to reduce noise and save energy
  • Protections for overload, short circuit, tele-communication, etc.
  • Emergency Power Off (EPO) protection
  • Remaining backup time display via LED or LCD (optional)
  • Extended backup time with battery pack

 

Specification 

MODEL

VRM-2000

VRM-3000

CAPACITY

2000VA

3000VA

1400W

2100W

INPUTVoltage

100V / 110V / 115V / 120V / 127V / 208V / 220V / 230V / 240V

110V-level mode: 60V to 69V under 40% load, 70V to 79V under 70% load, 80V to 144V with 100% load

220V-level mode: 120V to 139V under 40% load, 140V to 159V under 70% load, 160V to 276V with 100% load

Frequency

50Hz / 60Hz auto sensing

Phase

Single phase

Power factor

> 0.97

OUTPUTVoltage

110V / 115V / 120V or 208V / 220V / 230V / 240V ±2% (selectable output voltage)

Frequency

50Hz / 60Hz ±0.5%

Waveform

Pure sine wave

Phase

Single phase

Harmonic distortion

< 3% of T.H.D. at linear load

Efficiency

> 95% (high efficiency mode, AC to AC)

Connections

*Please refer below "Receptacle Options". Customized receptacle can be discussed.

PROTECTIONOverload protection

UPS automatic power off if overload exceeds 106% to 120% of nominal at 30 seconds; 121% to 150% for 10 seconds

Short circuit protection

UPS output cut off immediately or protected by input fuse or circuit breaker

Tele-communication

RJ45 x2

Alarm

Buzzer beeps under backup mode, battery low, battery charging fault, and overload

BATTARYType

Sealed, maintenance-free lead acid battery

Typical recharge time

4 hours to 90%

Battery quantity

12V 7Ah x6

12V 9Ah x6

Backup time (100% load)

6 minutes

5 minutes

Protection

Battery low cut-off without draining any current

GENERALDimension (W x D x H)

None

428 x 635 x 84 mm (2U)

Product weight (kg) 

33.6

34.3

Shipping weight (kg) 

36.7

38.3

Display (LED/LCD)

LED - line mode (green), bypass / battery mode (yellow), fault (red)
LCD - input / output voltage and frequency, on-line mode, backup mode, battery capacity, load level

Communication interface

Standard - RS-232; *Optional - USB B-type and/or SNMP

Audible noise

< 50dBA (1m from surface)

Ambient temperature

+0 °C to +40 °C

Storage temperature

-20 °C to +50 °C

Altitude

2000 meters max

Humidity

0-95%, non-condensing

Communication Interface

Model

LCD

CPU

SNMP

PFC

RS-232

USB

VGD-2000-RM

VGD-3000-RM

●Standard Function  ○Not Available   ◆Optional

 

Receptacle Options